F4034

Emergency-Stop

Bosch Rexroth · IndraDrive MPx02

¿Qué significa F4034 ?

This fault indicates that an emergency stop condition has been detected and activated on the IndraDrive MPx02, leading to an immediate and controlled shutdown of the drive. The E-stop signal is typically a hardwired input that overrides normal operation for safety.

Causas comunes

  • Activation of an external emergency stop push button or safety device.
  • Break in the emergency stop circuit wiring, leading to loss of the safety signal.
  • Faulty emergency stop contactor or relay in the safety circuit.
  • Incorrect wiring or configuration of the emergency stop input terminals on the IndraDrive MPx02.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Inspect all emergency stop buttons and safety interlocks in the machine or system to ensure none are pressed or active.

  2. 2

    Verify the integrity of the emergency stop safety circuit, checking for loose connections, damaged cables, or open contacts.

  3. 3

    Measure the voltage at the emergency stop input terminals of the IndraDrive MPx02 to confirm the expected safe state (e.g., 24VDC present for active state).

  4. 4

    Bypass the external E-stop circuit temporarily (if safe to do so for troubleshooting) to determine if the fault originates from the external wiring or an internal drive issue.

  5. 5

    Check safety parameters related to the E-stop function in the IndraDrive MPx02 for correct configuration.