833

%s-axis for switchover in SERCOS phase 3 not ready (covers 833-834, 836).

Bosch Rexroth · Motion Control

¿Qué significa 833 ?

The specified axis ('%s') is not ready for switchover to SERCOS phase 3, due to missing or incorrect identification number S-0-0021. This fault (covering codes 833-834 and 836) indicates the drive rejects the phase change because of parameter validation issues. It is a servo loop or drive fault.

Causas comunes

  • Drive rejection of SERCOS phase 3 switching due to missing ident number S-0-0021.
  • Drive rejection of SERCOS phase 3 switching due to incorrect ident number S-0-0021.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Read out ident number S-0-0021 of the affected axis.

  2. 2

    Correct any missing or wrong value for ident number S-0-0021.

  3. 3

    Initiate a new SERCOS startup after correcting the ident number.

Ver todos los códigos en este manual (60)
Datos técnicos verificados. Última actualización: March 2026