844

Selected SERCOS phase could not be implemented error in phase 0 transition.

Bosch Rexroth · Motion Control

¿Qué significa 844 ?

An error occurred during the transition to SERCOS phase 0, preventing the selected SERCOS phase from being successfully implemented. This is a servo loop or drive fault, indicating a critical issue in the SERCOS state machine, with no error recovery possible.

Causas comunes

  • Error during SERCOS phase 0 transition.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Measure input supply voltage and DC bus voltage at the affected drive and verify against nominal specifications.

  2. 2

    Inspect all SERCOS fiber optic cables for physical damage, proper routing, and secure connections at both controller and drive interfaces.

  3. 3

    Verify SERCOS communication parameters (e.g., ring configuration, cycle time, drive address) in both the controller and the drive against the machine's configuration backup.

  4. 4

    Check diagnostic LEDs on the SERCOS interface of the drive and controller for communication activity or error indications.