Bosch Rexroth · Motion Control

¿Qué significa 896 ?

A request for memory space, specifically for the internal management list, could not be satisfied, preventing the called function (%d) from executing. This is often caused by frequent loading of client modules that are waiting for a response from the NC, leading to resource exhaustion. This is a PLC error with no error recovery possible.

Causas comunes

  • Request for memory space for internal management list could not be satisfied.
  • Called function could not be performed due to memory shortage.
  • Frequent loading of client modules waiting for NC response.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify current firmware version of the Bosch Rexroth Motion Control unit and check for available updates.

  2. 2

    Inspect the loaded PLC/NC application program configuration, focusing on client module communication parameters (e.g., cycle times, buffer sizes, timeout values) and potential excessive resource allocation.

  3. 3

    Monitor NC/PLC system resource utilization (CPU load, memory usage, communication buffers) using integrated diagnostic tools to identify persistent high usage or leaks.

  4. 4

    Analyze the behavior of external client modules or connected systems to determine if they are initiating an unusually high frequency or volume of requests to the NC.