1316

Option software in slot B not supported/allowed

Danfoss · VLT AutomationDrive FC 301/302

¿Qué significa 1316 ?

The software installed on the option card in slot B is not compatible or permitted for use with the current drive configuration. This prevents proper integration and functionality of the option.

Causas comunes

  • Incorrect option card type installed in Slot B for the specific drive model or application.
  • Firmware on the option card in Slot B is of an incompatible type or version that is explicitly disallowed by the drive's main firmware.
  • A custom firmware version on the option card in Slot B is incompatible with the standard drive platform.
  • Configuration parameter (e.g., P14-41 Option B type) is set incorrectly for the installed hardware.
  • Corruption during a firmware update process on the option card in Slot B, leading to an unsupported state.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    1. Verify the part number and type of the option card physically installed in Slot B.

  2. 2

    2. Cross-reference the installed option card's part number against the drive's documentation to ensure it is a compatible accessory for the specific drive model.

  3. 3

    3. Check the firmware version of the option card in Slot B (e.g., P15-06) and compare it against the drive's compatibility list for supported versions.

  4. 4

    4. Ensure that relevant configuration parameters for Slot B (e.g., P14-41) are set to correctly reflect the installed option card type.

  5. 5

    5. If the option card is verified compatible but still errors, attempt to update the option card's firmware to the latest official version via a dedicated tool.

Ver todos los códigos en este manual (66)