Traduciendo...
5376–6231

Internal fault (Specific range)

Danfoss · VLT AutomationDrive FC 301/302

¿Qué significa 5376–6231 ?

A general internal fault has occurred within a specific range of internal error codes. This indicates an unspecified internal hardware or software malfunction that requires specialized attention.

Causas comunes

  • Corrupted firmware on the control board or a specific option module (e.g., due to power fluctuation during update).
  • Malfunction of internal power supply components on the control board or power board.
  • Critical sensor failure or out-of-range reading on an internal component (e.g., DSP temperature).
  • Data integrity error within internal memory (RAM/ROM) of the drive's CPU.
  • Electromagnetic interference (EMI) disrupting internal communication buses (e.g., CAN bus) within the drive.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Record the full fault code (e.g., 5376, 5377) and contact technical support with the drive's serial number and firmware version.

  2. 2

    Power cycle the frequency converter by switching off the main supply for at least 60 seconds.

  3. 3

    Verify input voltage (e.g., L1-L2, L2-L3, L3-L1) is stable and within nameplate specifications (e.g., 400V +/-10%).

  4. 4

    Check for loose connections on all internal ribbon cables and power connectors within the drive.

  5. 5

    Attempt a factory reset of the drive parameters (e.g., using parameter 14-22, depending on drive model) after backing up current settings.

Ver todos los códigos en este manual (66)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Danfoss VLT AutomationDrive FC 301/302