749
Serial Communication Error during Activation
Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters
¿Qué significa 749 ?
A serial communication error occurred while the Series 16i system was being activated after power-on. This indicates a problem in the communication link to the spindle amplifier, preventing normal startup.
Causas comunes
- A serial communication failure occurred during the boot-up sequence.
- The serial device failed to respond within the expected timeout period.
- Incorrect serial port settings (baud rate, parity, stop bits) during activation.
- A physical connection issue with the serial cable or connector.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify the serial cable connection between the controller and the device at terminal RS232-A.
- 2
Confirm the serial communication parameters (baud rate, parity) match between the controller and the device.
- 3
Measure the voltage levels on the serial communication lines (TXD, RXD).
- 4
Attempt to establish a basic serial communication test with the device.
Datos técnicos verificados. Última actualización: March 2026