H

Resistor Module Abnormal Discharge (2) (ECM)

Fanuc · Alpha i Series AC Servo Motor and Spindle

¿Qué significa H ?

The Capacitor Modules are not discharging due to a malfunction of the discharge circuit. This points to a failure within the Resistor Module's components or control.

Causas comunes

  • The braking resistor module is experiencing an abnormal discharge condition (second instance).
  • Persistent fault in the braking resistor system.
  • Contradictory signals from the braking resistor monitoring system.
  • Component failure within the braking resistor control or sensing circuitry.
  • Improper heat dissipation from the resistor, leading to thermal issues.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Inspect the Resistor Module for internal component failure or signs of overheating.

  2. 2

    Verify the functionality of the discharge circuit's control logic.

  3. 3

    Check resistance values of the Resistor Module components, if accessible.

Ver todos los códigos en este manual (29)
Datos técnicos verificados. Última actualización: March 2026