Traduciendo...
0233
Velocity Pulse Count Exceeded
Fanuc · Alpha i Series Servo Amplifier
¿Qué significa 0233 ?
This invalid parameter setting alarm occurs when initialization bit 0 is set to 1, and the number of velocity pulses configured exceeds the maximum allowable value of 13100. This indicates an incorrect setup for velocity feedback, potentially leading to calculation overflows.
Causas comunes
- Expected velocity pulses not received within the defined timeframe.
- Encoder signal interruption or degradation.
- Motor not rotating as expected.
- Excessive lag in velocity feedback loop.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Correct the number of velocity pulses in the relevant parameter so that its value is within 13100.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Fanuc Alpha i Series Servo Amplifier