Over-voltage of Capacitor Module (ECM)

Fanuc · Macro B CNC Programming

¿Qué significa 7 ?

An over-voltage condition has occurred in the Energy Charge Module's Capacitor Modules. This implies the capacitor bank is being charged beyond its rated voltage, potentially due to a fault in the charging control circuit, an issue with the Resistor Module, or an external over-voltage condition.

Causas comunes

  • Excessive voltage detected on the capacitor module (ECM) exceeding P1-75 limit.
  • Faulty power supply unit (ECM) supplying unstable voltage.
  • Incorrect input voltage configuration for the ECM.
  • Capacitor degradation leading to overcharge during operation.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Immediately stop the machine using the emergency stop button and open the external Main Circuit Contactor (MCC) of the Power supply.

  2. 2

    Measure the voltage across the Capacitor Modules (A06B-6158-H020) to confirm the over-voltage condition.

  3. 3

    Inspect the charging control circuit of the ECM (Control Module A06B-6158-H010) for proper regulation of the charging voltage.

  4. 4

    Verify the functionality of the Resistor Module (A06B-6158-H030), ensuring it can effectively discharge the Capacitor Modules at Emergency Stop or Alarm (page 578).

  5. 5

    Check the main power supply and any connected regenerative units for conditions that could lead to excessive voltage accumulation in the Capacitor Modules.