Count Error Alarm
Fanuc · Macro B CNC Programming
¿Qué significa SP0140 ?
The number of pulses between one phase Z and another from the spindle sensor is shifted by 4λ or more. This indicates a significant discrepancy in the phase Z signal, which is critical for absolute position detection, suggesting a fundamental sensor or feedback cable issue.
Causas comunes
- Capacitor module voltage is too low (below P1-04 threshold).
- Insufficient power supply to the DC link.
- Internal power supply fault within the ECM.
- High load demand draining the capacitor module.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check the spindle sensor for proper installation and alignment, particularly the phase Z ring, as mechanical issues can cause pulse shifts.
- 2
Inspect the spindle sensor cable (e.g., K97, page 297) for any damage or interference that could disrupt the phase Z signal.
- 3
Perform the output signal check method for the αiCZ sensor (Section 11.2.3.12, page 394) to confirm correct phase Z signal output and its relationship to phase A/B signals.
- 4
If the sensor ring was tightened with excessive torque during installation, deformation can occur, deteriorating detection precision. Use the recommended tightening torque (e.g., M3 screws at 1.5Nm for A860-2164-T411, page 366).
- 5
If no mechanical or cable issues are found, the spindle sensor may require replacement to restore accurate pulse counting.