COUNT MISS(INT)
Fanuc · Series 0i-D/0i Mate-D Maintenance
¿Qué significa 367 ?
This alarm on Fanuc Series 0i-D/0i Mate-D with αi/βi Pulsecoders indicates a position data count error from the built-in Pulsecoder. Root causes typically include Pulsecoder failure, electrical noise, or issues with signal transmission.
Causas comunes
- Internal failure of the Pulsecoder resulting in incorrect pulse counting.
- Electrical noise causing corruption or loss of position data pulses.
- Damaged or loose Pulsecoder cable leading to intermittent signal loss.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify the integrity of the Pulsecoder cable, checking for physical damage, proper shielding, and secure connections at both ends.
- 2
Investigate and mitigate any potential sources of electromagnetic interference (EMI) or noise affecting the Pulsecoder signal lines.
- 3
Check the mechanical mounting of the Pulsecoder for looseness or vibration that could lead to intermittent counting errors.
- 4
If noise mitigation, cabling, and mounting integrity are confirmed, replace the Pulsecoder unit.