Traduciendo...
382
COUNT MISS(EXT)
Fanuc · Series 0i-D/0i Mate-D Maintenance
¿Qué significa 382 ?
This alarm on Fanuc Series 0i-D/0i Mate-D indicates a position data count error from a separate (external) detector. This is typically due to a detector failure, signal corruption, or mechanical issues.
Causas comunes
- Internal failure of the external detector resulting in incorrect pulse counting.
- Damaged or loose cable leading to intermittent signal loss from the external detector.
- Excessive vibration or mechanical play affecting the external detector's accuracy.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Inspect the external detector's cable and connectors for proper seating, damage, or loose connections.
- 2
Verify the mechanical mounting of the external detector for stability and correct alignment.
- 3
Check for any excessive vibration or mechanical play in the system that could cause counting errors.
- 4
If physical inspection and mechanical checks do not resolve the issue, replace the external detector unit.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Fanuc Series 0i-D/0i Mate-D Maintenance