SERIAL DATA ERROR(EXT)
Fanuc · Series 0i-D/0i Mate-D Maintenance
¿Qué significa 385 ?
This alarm on Fanuc Series 0i-D/0i Mate-D indicates a communication interruption with a separate (external) detector. Common causes are cable disconnection, detector failure, or external noise affecting the serial data transmission.
Causas comunes
- Physical disconnection or damage to the external detector's communication cable.
- Electrical noise interfering with the serial data communication to/from the detector.
- Internal failure of the external detector preventing serial data transmission.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Inspect the external detector cable for physical damage, such as cuts, abrasions, or crushed sections.
- 2
Verify all connections of the external detector cable at both the detector and the SDU are secure and properly seated.
- 3
Check for and mitigate sources of electrical noise (e.g., from power contactors, switching devices) in the vicinity of the detector and its cabling.
- 4
Perform a continuity test on the external detector cable to ensure no broken wires or disconnections.
- 5
If cable integrity and noise issues are ruled out, replace the external detector unit.