PROGRAM DATA ERROR
Fanuc · Series 0i-D/0i Mate-D Maintenance
¿Qué significa ER01 ?
This Fanuc Series 0i-D/0i Mate-D PMC alarm indicates that the sequence program (ladder program) is invalid. This can be caused by incorrect program entry or a hardware fault within the PMC.
Causas comunes
- Incorrect sequence program data entry or corruption during loading.
- Logical or syntax errors within the sequence program.
- Hardware fault within the PMC module or its memory.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Re-enter or reload the sequence program (ladder program) using the PMC programmer.
- 2
Verify the integrity of the sequence program data against a known good backup file.
- 3
Check for any syntax errors, unsupported functions, or logical inconsistencies in the re-entered program.
- 4
If the error recurs even after correctly re-entering the program, consider a potential hardware issue with the PMC module.
- 5
Inspect the PMC module and its connections for any physical damage or loose components.