IE0007

EXCESS MAXIMUM REV. DATA

Fanuc · Series 0i-D/0i Mate-D Maintenance

¿Qué significa IE0007 ?

This Fanuc Series 0i-D/0i Mate-D malfunction prevention alarm indicates that the control detected a command specifying a value exceeding the maximum allowed speed for a rotational axis or spindle.

Causas comunes

  • NC program commands an excessively high spindle speed or rotational axis speed.
  • Machine parameter defining the maximum allowable speed is set too low.
  • Incorrect gearing or transmission ratio parameters are configured.
  • Software limit for maximum speed has been exceeded by the commanded value.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Examine the NC program (S-code, G-code) for any speed commands that exceed the machine's specified maximum limits.

  2. 2

    Verify the machine's maximum permissible spindle speed and feedrate parameters (e.g., Parameter 3701 for spindle max speed) are correctly set.

  3. 3

    Check the gearing or transmission settings in relevant parameters, ensuring they are correctly configured for the commanded speed range.

  4. 4

    Temporarily reduce the commanded speed in the NC program to test if the alarm clears.

  5. 5

    Ensure that the maximum speed set in parameters aligns with the physical capabilities of the motor and spindle/axis.