3010
No Machining Cycle Found (Figure Block Only)
Fanuc · Series 0i Manual Guide
¿Qué significa 3010 ?
This P/S alarm indicates that the control system could not find a valid machining cycle to execute. This occurs when the machining program specifies only a figure block without the necessary accompanying machining type block, making the intended operation undefined.
Causas comunes
- The machining program only contains positional data (figure block) without a cutting cycle.
- No valid G-code command for a cutting operation was found in the sequence.
- The program is incomplete, missing essential machining commands.
- Attempting to execute a contour definition without a subsequent machining command.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Modify the machining program by adding the required machining type block to define the intended machining cycle.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Fanuc Series 0i Manual Guide