3505
Invalid Machining Start Point
Fanuc · Series 0i Manual Guide
¿Qué significa 3505 ?
This MC alarm (specific to Series 30i) indicates that the machining start point defined in the program is invalid. This could be due to a coordinate outside the work envelope, an unreachable point, or a point that interferes with existing geometry, preventing the machining cycle from initiating correctly.
Causas comunes
- The computed start point for the cutting path is not achievable.
- Previous operation left the tool in an inaccessible position.
- Axis home position has been lost or incorrectly set.
- Program error in defining the first move of a contour.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Modify the machining program to specify a valid and reachable machining start point.
- 2
Alternatively, modify the machining program to enable automatic determination of the start point by the control system.