NC-PMC I/F ASSIGNMENT ERROR
Fanuc · Series 30i/31i/32i-MODEL B Parameter
¿Qué significa ER54 ?
This PMC alarm signifies an interface assignment error between the NC and the PMC. It is triggered when duplicate numbers are detected within the PMC assignment parameters, which prevents all Programmable Machine Controllers (PMCs) from starting due to conflicting address allocations.
Causas comunes
- Assignment error in the NC-PMC interface.
- Incorrect mapping of I/O signals between NC and PMC.
- Communication issue between the numerical controller and programmable machine controller.
- Conflicting I/O assignments in the system configuration.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Identify the parameters responsible for NC-PMC interface assignment (e.g., specific PMC address allocation parameters).
- 2
Check all identified PMC assignment parameters to ensure that no duplicate numbers are set across them.
- 3
Verify that each PMC address is uniquely allocated and correctly specified in its corresponding parameter.
- 4
After correcting any duplicate assignments, turn the CNC power off and then back on to apply the changes and reinitialize the PMCs.