386
DATA TRANS. ERROR(EXT)
Fanuc · Series 30i/31i/32i-MODEL B Plus
¿Qué significa 386 ?
This external alarm signals a communication data error from the separate detector, primarily caused by noise. Unstable position data from the separate detector can lead to erratic or inaccurate control.
Causas comunes
- Noise causing unstable position data from the separate detector.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check CNC diagnosis information No.356 (Built-in detector) and No.357 (Separate detector) for incremented values, which indicate noise effects. The value is cleared when the CNC unit is powered off.