d2

Sensor (Serial) Communication Disconnected

Fanuc · Series 30i/31i/32i-MODEL B Plus

¿Qué significa d2 ?

This alarm indicates that communication between the serial sensor and the Spindle Amplifier is disconnected. This can be caused by incorrect parameter settings, an unsupported Spindle Amplifier, cable issues, or a defective Spindle Amplifier.

Causas comunes

  • Parameter setting error for the sensor.
  • Unsupported Spindle Amplifier.
  • Broken or incorrectly connected sensor communication cable.
  • Defective Spindle Amplifier.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the sensor setting parameters by referring to the 'START-UP' section in the FANUC AC SPINDLE MOTOR α i series Parameter Manual (B-65280EN).

  2. 2

    Verify Spindle Amplifier compatibility by checking 'PARAMETERS RELATED TO DETECTORS' in the FANUC SERVO AMPLIFIER α i series Descriptions (B-65282EN).

  3. 3

    Replace the sensor communication cable or check its connection for integrity.

  4. 4

    Replace the Spindle Amplifier or Spindle Amplifier control printed-circuit board.

Ver todos los códigos en este manual (38)