Communication error between amplifiers
Fanuc · Series 30i/31i/32i-MODEL B Plus
¿Qué significa P ?
A communication error has occurred between various amplifiers. This issue is typically caused by a defective connector or cable (CXA2A/B) used for inter-amplifier communication, or an internal failure within the Servo Amplifier. This error prevents proper control signal exchange.
Causas comunes
- Connector/cable (CXA2A/B) defective
- Servo Amplifier failure
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check the integrity and ensure secure connection of connector CXA2A/B between the amplifiers.
- 2
If the connector and cable are confirmed to be in good condition, replace the Servo Amplifier.
Datos técnicos verificados. Última actualización: March 2026