8

PSMR Excessive Short-Term Regenerative Power

Fanuc · Series 30i CNC

¿Qué significa 8 ?

This alarm occurs in the Power Supply Module with Regenerative (PSMR) when the system experiences excessive short-term regenerative power. This condition indicates that the energy generated by the motor during deceleration or braking exceeds the capacity of the regenerative resistance or circuit. It can lead to overvoltage on the DC link or damage to the regenerative components.

Causas comunes

  • Insufficient regenerative resistance specification for the application.
  • Failure within the regenerative circuit components.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Review the specification of the regenerative resistance to ensure it is appropriately sized for the application's regenerative power requirements.

  2. 2

    If the regenerative circuit is abnormal after resistance review, replace the PSMR unit.

Ver todos los códigos en este manual (20)
Datos técnicos verificados. Última actualización: March 2026