326
Fan 1 error
Fronius · Primo GEN24 Operating Instructions
¿Qué significa 326 ?
This code indicates an error with Fan 1, one of the inverter's internal cooling fans. A fan malfunction can lead to insufficient cooling and subsequent overtemperature conditions, causing a short-term interruption in energy feeding.
Causas comunes
- Fan 1 motor failure or blockage by debris.
- Faulty fan speed sensor or control circuit.
- Disconnection of the fan power supply or signal cable.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
If the status code is displayed continuously, notify a Fronius-trained service engineer for fan inspection and replacement.
- 2
Inspect Fan 1 for any visible obstructions or damage.
- 3
Perform an AC reset to attempt to clear transient fan control errors.