416

No communication possible between power stage set and control system.

Fronius · Primo GEN24 Operating Instructions

¿Qué significa 416 ?

This code indicates a failure in communication between the inverter's power stage set and its control system. This prevents normal operation, but the inverter will automatically attempt to re-establish communication and resume feeding energy into the grid.

Causas comunes

  • Faulty communication link (e.g., ribbon cable, bus connection) between the power and control boards.
  • Malfunction of communication transceivers on either the power stage or control system.
  • Electromagnetic interference disrupting the communication channel.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    If the status code is displayed continuously, notify a Fronius-trained service engineer for diagnosis.

  2. 2

    Perform an AC reset by cycling the automatic circuit breaker to restart the inverter's internal communication.

  3. 3

    Inspect internal communication cables for damage or loose connections.