902

DC voltage too low for backup power

Fronius · Primo GEN24

¿Qué significa 902 ?

The DC voltage from the battery is too low to initiate or sustain backup power operation with the Fronius Primo GEN24 208-240 inverter. This indicates the battery is either critically discharged or faulty.

Causas comunes

  • DC voltage too low for backup power.
  • Battery deeply discharged.
  • Battery fault.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the battery's state of charge (SoC) and voltage; ensure it's above the minimum threshold required for backup power. The battery may need charging from the grid (if available) or PV.

  2. 2

    Measure the battery voltage at the Fronius Primo GEN24 208-240 inverter's DC terminals to confirm it aligns with the battery's internal readings and is sufficient for backup operation.

  3. 3

    Inspect DC cables and connections between the battery and inverter for any issues causing voltage drops.

  4. 4

    Refer to the battery manufacturer's manual for specific low-voltage recovery procedures or diagnostics if the battery is faulty or deeply discharged.

  5. 5

    Confirm that the battery parameters in the inverter settings are correctly configured for the connected battery model.