Traduciendo...
1173

ArcContinuousFault

Fronius · Symo Advanced

¿Qué significa 1173 ?

An electric arc has been identified within the PV system, and the inverter has reached the maximum allowed number of automatic reconnections within a 24-hour period. This fault indicates a persistent arc condition requiring immediate investigation. The inverter's operating LED flashes red, signifying a critical issue that could lead to component damage or personal injury if not addressed.

Causas comunes

  • An electric arc has been continuously identified on the PV system.
  • The maximum number of automatic connection attempts within 24 hours has been reached due to persistent arc fault detection.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Before confirming this status, thoroughly check the entire photovoltaic system for any possible damage and ensure all damaged components are repaired by qualified specialists.

  2. 2

    Keep the sensor pressed on the inverter for 3 seconds (maximum 6 seconds) to attempt clearing the fault.

  3. 3

    On the inverter's user interface, navigate to the System > Event Log menu area and confirm the status 1173 - ArcContinuousFault.

  4. 4

    Alternatively, on the inverter's user interface, navigate to the Notifications user menu and confirm the status 1173 - ArcContinuousFault.

Ver todos los códigos en este manual (41)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas