Current limit exceeded!

Current Limit Exceeded

Fronius · TPS i Welding Machine

¿Qué significa Current limit exceeded! ?

This safety function activates during MIG/MAG welding when the characteristic-dependent current limit is reached. If the welding power is too high, the arc may become smaller and extinguish. The welding machine automatically reduces wire speed and welding power to prevent arc extinguishment, and a corresponding message appears in the status bar.

Causas comunes

  • Welding power is too high for the selected characteristic.
  • Characteristic-dependent current limit has been reached.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Reduce the wire speed parameter.

  2. 2

    Reduce the welding current parameter.

  3. 3

    Reduce the welding voltage parameter.

  4. 4

    Reduce the material thickness parameter.

  5. 5

    Increase the distance between the contact tip and the workpiece.