Power stage in axis %.1s too weak
Heidenhain · NC Control
¿Qué significa 2188 F050 ?
The power stage (drive) for the displayed axis is determined to be too weak. This suggests that the drive is undersized for the motor or the application's demands, leading to it being overloaded.
Causas comunes
- Power stage for displayed axis too weak.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify that the power stage (drive) is correctly sized for the motor and the application's torque/power requirements for the specified axis.
- 2
Check for any excessive mechanical load, binding, or friction on the axis that could be overworking the power stage.
- 3
Review the motor parameters in the NC control (e.g., rated current, peak current) to ensure they are correctly set and consistent with the drive's capabilities.
- 4
Inspect the power supply voltage to the drive; ensure it is stable and within specification under load conditions.