2189 F060

%.1s motor enc. line count too high

Heidenhain · NC Control

¿Qué significa 2189 F060 ?

The configured motor encoder line count for the displayed axis is too large. This indicates a mismatch between the encoder's actual resolution and the value set in the NC control's parameters.

Causas comunes

  • Motor encoder line count too large for the displayed axis.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the configured motor encoder line count parameter for the specified axis in the NC control against the actual motor encoder's nameplate data or datasheet.

  2. 2

    Ensure the encoder type and resolution are compatible with the NC control's specifications for that axis.

  3. 3

    Check the motor encoder cabling for any signs of interference, damage, or improper shielding that could lead to erroneous readings.

  4. 4

    If the parameter is correct, consider if an incorrect encoder model with a higher line count has been installed or if there's a fault in the control's encoder signal processing hardware.

Ver todos los códigos en este manual (58)
Datos técnicos verificados. Última actualización: March 2026