2194 F110

Motor %.1s: t-max incorrect

Heidenhain · NC Control

¿Qué significa 2194 F110 ?

The T-MAX (maximum temperature) of the motor for the displayed axis is incorrect. This indicates a configuration issue where the defined maximum temperature limit for the motor does not match its specifications or requirements.

Causas comunes

  • T-MAX (maximum temperature) parameter for the motor on the displayed axis is incorrectly configured.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify the motor's maximum temperature parameter setting (T-MAX) in the NC control for the specified axis against the motor nameplate data.

  2. 2

    Inspect the motor and its cooling system (e.g., fan, heatsink) for blockages, dust accumulation, or any signs of actual overheating.

  3. 3

    Check the motor temperature sensor and its wiring for proper connection, integrity, and functionality.

  4. 4

    Monitor motor load during operation to ensure it is within its continuous rating, as sustained overload can lead to overheating.

Ver todos los códigos en este manual (58)
Datos técnicos verificados. Última actualización: March 2026