2203 F200

%.1s motor enc. zn ampl. too small

Heidenhain · NC Control

¿Qué significa 2203 F200 ?

The ZN amplitude of the encoder (ERN 1381) for the displayed axis is too small. This indicates a problem with the encoder signal integrity, potentially leading to inaccurate position feedback.

Causas comunes

  • ZN amplitude of the encoder (ERN 1381) for the displayed axis is too small.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the motor encoder (ERN 1381) cabling for the specified axis, including shielding and ground connections, for damage, loose contacts, or interference.

  2. 2

    Inspect the encoder itself for signs of physical damage, contamination (e.g., oil, dust), or mounting issues that could affect signal generation.

  3. 3

    Verify the power supply voltage to the encoder is present and stable, within the specified operating range.

  4. 4

    If possible, use an oscilloscope to measure the ZN signal amplitude directly at the encoder output and at the control input to detect signal degradation.

Ver todos los códigos en este manual (58)