CC%d BA2 only one axis allowed
Heidenhain · NC Control
¿Qué significa 7949 A043 ?
In operating mode BA2 with open safety doors, the simultaneous movement of more than one axis is not allowed. This error is triggered when this safety rule is violated.
Causas comunes
- Simultaneous movement of more than one axis detected in operating mode BA2 with open safety doors.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Ensure all axes are at a complete standstill before attempting any movement in BA2 operating mode with open safety doors.
- 2
Confirm that only one axis is commanded to move at a time when operating in BA2 mode with safety doors open.
- 3
Verify the functionality and correct operation of the safety door interlocks to ensure their status is accurately detected by the NC control.
- 4
Review the NC program or manual jogging procedures to ensure strict adherence to the single-axis movement rule in this specific operating mode.