CC SBH rot. speed too high %.2s
Heidenhain · NC Control
¿Qué significa 7954 A840 ?
The maximal permissible velocity of the standstill monitoring (SBH) was exceeded. This indicates that the axis moved faster than allowed when standstill monitoring should have been active.
Causas comunes
- Maximal permissible velocity of the standstill monitoring was exceeded.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify that the axis is indeed at standstill or below the SBH speed limit when standstill monitoring is active.
- 2
Inspect the drive and encoder feedback system for the affected axis to ensure accurate speed measurement and reliable control.
- 3
Check the SBH (Safe Controlled Stop or Standstill Monitoring) parameters in the NC control to ensure they are configured correctly and the speed limit is appropriate for the application.
- 4
Look for any external mechanical forces or disturbances that could cause unexpected movement or speed when standstill is expected.