231-A001
Cancelation of brake-test call monitoring
Heidenhain · TNC CNC Controllers
¿Qué significa 231-A001 ?
This error indicates that the brake-test call monitoring was canceled. This typically happens if protective doors are opened during the brake test, or if the drive-ready signal is not present during the monitoring period.
Causas comunes
- Protective door(s) were opened during the brake test.
- No drive-ready signal was present during the brake-test call monitoring.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Ensure all protective doors are closed and securely latched before and during the brake test.
- 2
Verify that the drive is ready (drive-ready signal is active) before initiating and throughout the brake-test call monitoring.
- 3
Check the status of safety door interlocks and associated sensors for correct operation.
- 4
Inspect wiring for protective door switches and drive-ready signal for integrity and proper connection.