Quick stop with probe detection is active
Indramat · IndraDrive MPx02
¿Qué significa E8035 ?
The IndraDrive MPx02 is currently executing a quick stop sequence, and during this process, a probe input (e.g., for homing, precise position capture, or a limit switch) has become active. This warning ensures the technician is aware of the concurrent events, which might be normal or indicate an unexpected interaction in the control logic.
Causas comunes
- A quick stop command was initiated while a probe input (e.g., touch probe, homing switch) was already active or became active unexpectedly.
- The timing or sequencing of quick stop and probe detection events in the control program is incorrect or unforeseen.
- Noisy probe input signal causing a false detection during the quick stop.
- An unexpected mechanical event triggering a probe while the quick stop is active.
- Incorrect parameterization of quick stop reaction in relation to probe inputs.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify the sequence of events and control logic in the master controller (PLC/CNC) that initiates the quick stop command and monitors the probe input.
- 2
Ensure that the probe input is intended to be active during a quick stop for the specific application (e.g., emergency homing or collision detection). If not, investigate why it became active.
- 3
Check the wiring and shielding of the probe input signal to the IndraDrive MPx02 to ensure it is not susceptible to electrical noise that could trigger it falsely.
- 4
Review the parameters related to quick stop and probe inputs in the drive configuration for any settings that might cause unexpected interactions.
- 5
Perform a controlled test of the quick stop and probe functions to observe their interaction.