Positive travel range limit switch activated
Indramat · IndraDrive MPx02
¿Qué significa E8043 ?
The IndraDrive MPx02 has detected that the physical positive travel range limit switch (hardware limit switch) has been activated. This is a critical warning indicating that the axis has reached or exceeded its absolute positive mechanical limit, preventing further movement in that direction to protect the machine.
Causas comunes
- Axis has physically traveled beyond its intended positive working range, activating the limit switch.
- Incorrect homing procedure or offset causing the axis to reference too close to the limit switch.
- Faulty limit switch or wiring, leading to false activation.
- Aggressive motion profile or uncontrolled movement causing mechanical overtravel.
- Accumulated position error over time, causing the axis to drift into the limit.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Manually jog the axis in the negative direction, away from the limit switch, until it deactivates.
- 2
Inspect the positive travel range limit switch for physical damage, misalignment, or contamination that might cause false activation.
- 3
Verify the wiring of the limit switch to the IndraDrive MPx02's digital input, ensuring it is correctly connected and functioning.
- 4
Review the homing procedure and position reference settings to ensure the axis operates well within its physical travel limits.
- 5
Adjust motion parameters (e.g., deceleration, commanded position limits) to prevent the axis from approaching the physical limit switch during normal operation.