Traduciendo...
21

Drive Runaway A2

Indramat · ServoDyn D Servo Drive

¿Qué significa 21 ?

This "Drive Runaway Axis 2" error indicates a conflict between the direction of the Axis 2 encoder feedback and the commanded polarity of Axis 2. This means the drive is trying to move in one direction, but the encoder reports movement in the opposite, or there's a misconfiguration in feedback/command polarity.

Causas comunes

  • Direction Axis 2 parameter (P46) is incompatible with the wiring polarity of the Axis 2 encoder or the E1/E2 command inputs.
  • Encoder Data A2 parameter (P41) does not accurately reflect the encoder used on Axis 2, leading to incorrect interpretation of feedback.
  • RPM/Volts in Drive Sensit. A2 parameter (P43) does not match the Axis 2 amplifier's command input (E1/E2) characteristics.
  • Physical movement of Axis 2 (e.g., by external forces) without a corresponding command voltage, causing a discrepancy.
  • Incorrect wiring polarity of the Axis 2 encoder or the E1/E2 command inputs to the amplifier.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify that Parameter P46 (Direction Axis 2) is compatible with the wiring polarity of the Axis 2 encoder and the E1/E2 command inputs to the drive amplifier.

  2. 2

    Confirm that Parameter P41 (Encoder Data A2) accurately matches the specifications of the absolute or incremental encoder installed on Axis 2.

  3. 3

    Ensure Parameter P43 (Drive Sensit. A2) RPM/Volt setting corresponds to the actual RPM/Volt scaling of the Axis 2 amplifier's command input (E1/E2).

  4. 4

    Inspect Axis 2 for any mechanical binding or external forces that could cause movement independent of electrical commands.

  5. 5

    Check all wiring connections and polarities for the Axis 2 encoder and the E1/E2 command inputs to ensure they are correct and secure.

Ver todos los códigos en este manual (51)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Indramat ServoDyn D Servo Drive