RS Checksum Error
Indramat · ServoDyn D Servo Drive
¿Qué significa RS 04 ?
This serial communication error occurs when the checksum calculated by the CLM01.3-M from received data does not match the checksum transmitted by the sending device. This indicates data corruption during transmission, if checksum is enabled.
Causas comunes
- Data corruption or loss during serial transmission between the sending device and the CLM01.3-M.
- Checksum calculation error on the sending device, resulting in an incorrect transmitted checksum.
- Parameter 81 (Serial Interface Functions) is configured incorrectly for checksum (e.g., checksum enabled on one side, disabled on the other).
- Noise or interference on the serial communication line.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify that the checksum being transmitted by the sending device is calculated correctly as per Chapter 7 (Serial Interface).
- 2
Ensure that Parameter 81 (Serial Interface Functions) on the CLM01.3-M is configured to match the checksum setting (enabled/disabled) of the sending device.
- 3
Re-transmit the information after confirming checksum calculation and settings.
- 4
Inspect the serial communication cable for damage, proper shielding, and correct connections.
- 5
If possible, use diagnostic tools to monitor the serial data stream and verify checksum integrity at different points in the communication path.