Overvoltage
Kone · CMXC-022 Frequency Control Upgrade Kit
¿Qué significa 2 ?
The R&M Materials Handling Frequency Converter has detected an overvoltage condition, which could be caused by an excessively high supply voltage or a fault in the braking resistor circuit. Issues such as a failure of the resistor itself or a break in its wiring can trigger this fault.
Causas comunes
- Supply voltage exceeding the rated input range
- Failure of the braking resistor
- Break in the braking resistor wiring
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Measure the supply voltage and compare it to the specified hoist supply voltage on the hoist type plate
- 2
Measure the resistance of the braking resistor
- 3
Perform a visual inspection of the braking resistor and its wiring connections