Generator Current Limit/Deceleration Ramp Supervision

Kone · CMXC-022 Frequency Control Upgrade Kit

¿Qué significa 56 ?

The R&M Materials Handling Frequency Converter is unable to stop the motor within the configured deceleration ramp due to excessive regenerative current. This fault typically occurs when the motor's kinetic energy during deceleration exceeds the drive's capacity to dissipate it or the braking resistor capacity.

Causas comunes

  • Inverter cannot stop the motor with the current deceleration ramp stretching settings

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Increase the value of parameter P1.8 (Deceleration Time)

  2. 2

    Increase the value of parameter P11.1 (Ramp Stretching)