Traduciendo...
71

Brake control

Kone · CMXC-022 Frequency Control Upgrade Kit

¿Qué significa 71 ?

An error has been detected within the brake control circuit of the R&M Materials Handling Frequency Converter, indicating a malfunction that could prevent the brake from engaging or disengaging properly. This poses a significant safety risk, especially in hoist applications.

Causas comunes

  • Error detected in the brake control circuit

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check and repair the brake control circuit wiring

  2. 2

    Measure the brake coil resistance and compare to specifications

  3. 3

    Replace the brake if its resistance is outside specifications

  4. 4

    If the problem recurs, replace the inverter

Ver todos los códigos en este manual (40)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Kone CMXC-022 Frequency Control Upgrade Kit