105

BMS Alarm

Kone · Elevator Control

¿Qué significa 105 ?

An alarm has been triggered by the Battery Management System (BMS), indicating a non-critical issue with the battery. This condition limits the drive speed.

Causas comunes

  • BMS detecting a minor anomaly related to battery health, temperature, or cell imbalance.
  • Battery parameters nearing their limits (e.g., charge/discharge temperature, voltage).
  • Intermittent communication issue with the BMS.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify battery terminal voltage against specified nominal values under both no-load and charge conditions.

  2. 2

    Inspect all battery power and communication cabling for loose connections, corrosion, or physical damage.

  3. 3

    Measure the charging voltage and current delivered to the battery by the integrated charging unit.

  4. 4

    Check the elevator control unit's diagnostic log for detailed BMS sub-faults or specific battery status readings.