BATTERY LOW

Kone · Elevator Control

¿Qué significa 1066 ?

The motor controller (codes 1066, 2066, 3066) has detected a low battery voltage condition. This indicates insufficient power supply to the drive system. The specific lift reaction is controller dependent.

Causas comunes

  • Battery significantly discharged below operational threshold.
  • Aging battery with reduced capacity.
  • High current draw exceeding battery's instantaneous capability.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Measure the voltage of the motor controller's backup battery pack and compare against manufacturer specifications.

  2. 2

    Inspect all battery terminals, connectors, and associated cabling for corrosion, damage, or loose connections.

  3. 3

    Verify the output voltage and charging current from the dedicated battery charging circuit to the battery pack.

  4. 4

    Check the main input power supply voltage at the motor controller (drive system) terminals and confirm it is within specified limits.