18

Pothole Guard Fault

Kone · Elevator Control

¿Qué significa 18 ?

A fault has been detected in the pothole guard system, compromising its ability to operate correctly. This fault disables both lifting and driving functions for safety.

Causas comunes

  • Pothole guard sensor malfunction or system failure.
  • Pothole guard circuit open or shorted.
  • Mechanical damage preventing pothole guard deployment or retraction.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Inspect the pothole guard mechanism for physical obstructions, damage, or excessive wear that might prevent its free movement or proper deployment/retraction.

  2. 2

    Check all electrical wiring and connections to the pothole guard sensors and actuators for looseness, damage, or corrosion.

  3. 3

    Verify the status of the pothole guard position sensors via the Kone Kone Elevator Control's diagnostic interface or I/O status screen, confirming their accurate state.

  4. 4

    Measure the supply voltage at the pothole guard actuator terminals to ensure it matches the specified nominal voltage according to the wiring diagrams.

Ver todos los códigos en este manual (60)