Platform Load is over 90%

Kone · Elevator Control

¿Qué significa 90 ?

The detected load on the platform exceeds 90% of its rated capacity. This is a warning only, indicating close proximity to the maximum load limit.

Causas comunes

  • Platform loaded very close to its maximum capacity.
  • Malfunction of the platform overload sensor, providing an inaccurate reading.
  • Temporary load spikes triggering the sensor.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify load weighing system (LWS) calibration parameters in the Kone Kone Elevator Control system against the latest documentation and factory settings.

  2. 2

    Inspect all load weighing device (LWD) sensors and their mounting hardware for physical damage, obstructions, or improper installation that could affect readings.

  3. 3

    Inspect all wiring and connections from the load weighing device (LWD) sensors to the Kone Kone Elevator Control for signs of damage, corrosion, or looseness.

  4. 4

    Observe elevator operation during typical load cycles and monitor the reported load value in the control system for consistency and accuracy, comparing with estimated actual loads.