STOP 0
Safety Stop 0
Kuka · Industrial Robots Use & Programming
¿Qué significa STOP 0 ?
A Safety STOP 0 has been triggered and executed by the safety controller. This is an immediate and uncontrolled stop where the safety controller de-energizes all robot drives and applies the brakes without a deceleration ramp. It is the highest priority safety stop.
Causas comunes
- Detection of movement during a safe operational stop (standstill monitoring violation).
- Activation of an external safety device (e.g., safety mat, laser scanner, photoelectric curtain).
- Internal fault detected within the safety controller hardware or software.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Identify the specific safety device or condition that triggered the STOP 0 (e.g., open safety gate, tripped safety mat).
- 2
Clear the triggering condition (e.g., close safety gate, remove obstruction from safety mat).
- 3
Acknowledge any pending safety messages on the smartPAD.
- 4
Re-activate robot drives through the appropriate controller interface.
Datos técnicos verificados. Última actualización: March 2026