Traduciendo...
MR10

Alarm Space 10 Violation

Kuka · KK53Y Servo Motor

¿Qué significa MR10 ?

The MR10 signal indicates a violation of monitoring space 10. A '0' state on this signal means that monitoring space 10 is currently being infringed upon. If monitoring space 10 is intentionally inactive, the system considers it violated by default, and the associated safe output MR10 will be in the '0' state.

Causas comunes

  • Alarm condition triggered in Space 10 of the monitoring system.
  • Parameter P10 has exceeded its defined alarm threshold.
  • Sensor associated with Space 10 reporting an out-of-bounds value.
  • Configuration error in Space 10 alarm limits.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Identify the configured boundaries for monitoring space 10 in the robot's programming environment (e.g., using KUKA WorkVisual).

  2. 2

    Physically inspect the robot's current position and ensure no part of the manipulator, external axes, or tooling is entering or has entered the defined monitoring space 10.

  3. 3

    If monitoring space 10 is intended to be inactive, verify this configuration in WorkVisual and acknowledge that the MR10 signal will default to a '0' (violated) state.

Ver todos los códigos en este manual (17)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas