50
OH-Trip (Overtemperature, heat sink)
Kuka · KR C2 Robot Controller
¿Qué significa 50 ?
This fault indicates an overtemperature condition detected at the heat sink of the device. This implies insufficient heat dissipation, potentially due to blocked airflow, a faulty cooling fan, or excessive ambient temperature, which can lead to thermal shutdown and component damage.
Causas comunes
- OH-Trip: Overtemperature detected on heatsink (P1-11).
- Insufficient cooling or ventilation for the drive.
- Excessive ambient temperature in the control cabinet.
- Drive operating at high load continuously.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify cooling fan operation by observing its rotation and airflow direction.
- 2
Measure ambient temperature around the device enclosure — ensure it is within specified operating limits.
- 3
Clear any dust or debris from the heat sink fins and cooling air vents using compressed air.