Cabinet temperature too high PMx

KPS Interior Overtemperature

Kuka · KR C2 Robot Controller

¿Qué significa Cabinet temperature too high PMx ?

An overtemperature condition has been detected inside the KPS module (PMx). This indicates that the cabinet ventilation is not functioning correctly, leading to an elevated interior temperature affecting the KPS.

Causas comunes

  • Ambient temperature within the control cabinet is excessive.
  • Cabinet cooling system (fans, filters) is inadequate or malfunctioning.
  • External heat sources impacting the cabinet temperature.
  • High power dissipation from internal components.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the cabinet ventilation system for proper operation and sufficient airflow.

  2. 2

    Verify that cabinet air filters are clean and not obstructed.

Ver todos los códigos en este manual (58)